Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. bras. oftalmol ; 81: e0043, 2022. tab, graf
Article in English | LILACS | ID: biblio-1387977

ABSTRACT

ABSTRACT Objective: To evaluate the efficacy of low-cost nucleus fragmenting forceps designed to reduce the use of ultrasound during phacoemulsification. Methods: A total of 60 pig eyes enucleated 10 hours before were placed in the microwave oven, at maximum power for 10 seconds, to form cataracts with hardness comparable to a grade IV nucleus in the Lens Opacities Classification System III. Cataract extraction was performed using the Centurion® phacoemulsifier (Alcon Laboratories, Geneve, Switzerland) and Leica M620 microscope. All eyes were submitted to the pre-chop technique dividing the nucleus into four parts. After the pre-chop, the quadrants in 30 eyes were phacoemulsified with the torsional mode and were fragmented in the remaining 30 eyes after the pre-chop was with the fragmentation forceps before torsional mode phacoemulsification. The device was calibrated for all eyes by applying the following parameters: 40% linear torsional phacoemulsification; intraocular pressure of 65 mmHg; the linear vacuum of 600 mmHg; aspiration flow of 40 ccs/minute. After each procedure, the following was recorded: cumulative dissipated energy; equivalent average torsional amplitude; equivalent average ultrasonic power; estimated aspirated fluid; ultrasound total time; and total aspiration time. Statistical analysis was performed using the Kruskal-Wallis test and the IBM Statistical Package for Social Sciences. The p-value <0.05 was considered statistically significant. Results: There was a statistically significant reduction favoring the use of the nucleus fragmenting forceps in all parameters, except for the average torsional amplitude. Conclusion: The use of the nucleus fragmenting forceps contributed to improving the efficacy of torsional phacoemulsification in enucleated pig eyes.


RESUMO Objetivo: Avaliar a eficácia de uma pinça fragmentadora de núcleo, de baixo custo, desenvolvida para reduzir o uso de ultrassom durante a emulsificação do núcleo. Métodos: Sessenta olhos de porco com 10 horas de enucleação foram colocados no forno de microondas, em potência máxima por 10 segundos, para a formação de catarata com dureza comparável à de um núcleo grau IV na Lens Opacities Classification System III. A extração da catarata foi realizada com o facoemulsificador Centurion® (Alcon Laboratories, Genebra, Suíça) e microscópio Leica M620. Todos os olhos foram submetidos a técnica de pre-chop, dividindo o núcleo em quatro partes. Em 30 olhos, após o pre-chop, foi feita a facoemulsificação dos quadrantes com o modo torsional e, nos outros 30 olhos, após o pre-chop, cada quadrante foi fragmentado com a pinça antes da facoemulsificação com o modo torsional. O aparelho foi calibrado para todos os olhos com os seguintes parâmetros: faco torsional linear 40%; pressão intraocular 65 mmHg; vácuo linear 600mmHg e fluxo de aspiração 40cc/minuto. Após cada procedimento, verificaram-se energia dissipada acumulada; média da amplitude do faco torsional; média equivalente do poder ultrassônico; líquido aspirado estimado; tempo total de ultrassom e tempo total de aspiração. A análise estatística foi realizada utilizando o teste de Kruskal-Wallis com o IBM Statistical Package for Social Sciences. Valor de p<0,05 foi considerado estatisticamente significante. Resultados: Houve redução estatisticamente significante em favor do uso da pinça fragmentadora de núcleo em todos os parâmetros, menos na média de amplitude do faco torsional. Conclusão: O uso da pinça fragmentadora de núcleo contribuiu para melhorar a eficácia do faco torsional em olhos de porco enucleados.


Subject(s)
Animals , Surgical Instruments , Ultrasonic Therapy , Phacoemulsification/instrumentation , Phacoemulsification/methods , Lens Nucleus, Crystalline/surgery , Sonication/adverse effects , Swine , Cataract/classification , Eye Enucleation
2.
Rev. Col. Bras. Cir ; 48: e20213206, 2021. graf
Article in English | LILACS | ID: biblio-1356708

ABSTRACT

ABSTRACT The use of mobile phones has dramatically increased all over the world. Such revolution in the communication amongst individuals has a great impact in patient care, supporting their self-management and promoting shared responsibility with health services. Given that improved communication facilitates compliance with scheduled procedures and reduces surgical cancellations, the current work aims to develop a communication tool named Surgery Remember@ to mitigate surgical suspensions due to patient absenteeism. The present article is a study of technological production divided into four chapters: literature review; analysis of the hospital administrative profile; software development; and process mapping for software implementation. Taking into account that in the last three years the problem of absenteeism was the main cause of institutional surgical cancellations; the development of Surgery Remember@ endeavours to reduce surgery cancellations, improving efficiency and reducing costs. It is known that sending messages three days before the surgical procedure makes it possible to replace patients in the event of cancellations, optimizing the human and material resources in the operating room. The confirmation of the pre-aesthetic consultation is also positive, for it allows the verification of perioperative assistance improvement. Hence, besides being viable and easy to implement, the software developed allows the addition of other features based on user requirements, proving to be an asset to reduce surgery cancellations.


RESUMO O uso de telefones celulares aumentou dramaticamente em todo o mundo. Essa revolução na comunicação entre os indivíduos tem impacto no cuidado ao paciente, apoiando sua autogestão e promovendo a responsabilidade compartilhada com os serviços de saúde. Tendo em vista que a melhoria da comunicação facilita o cumprimento dos procedimentos programados e reduz os cancelamentos cirúrgicos, o presente trabalho tem como objetivo desenvolver uma ferramenta de comunicação denominada Surgery Remember@ para mitigar as suspensões cirúrgicas por absenteísmo do paciente. O presente artigo é um estudo da produção tecnológica dividido em quatro capítulos: revisão de literatura; análise do perfil administrativo do hospital; desenvolvimento de software; e mapeamento de processos para implementação de software. Tendo em conta que nos últimos três anos o problema do absenteísmo foi a principal causa de cancelamentos cirúrgicos institucionais o desenvolvimento do Surgery Remember@ se apresenta como esforço para reduzir os cancelamentos de cirurgias, melhorando a eficiência e reduzindo custos. Sabe-se que o envio de mensagens três dias antes do procedimento cirúrgico possibilita a reposição de pacientes em caso de cancelamentos, otimizando os recursos humanos e materiais da sala cirúrgica. A confirmação da consulta pré-anestésica também é positiva, pois permite verificar a melhora da assistência perioperatória. Assim, além de viável e de fácil implementação, o software desenvolvido permite agregar outros recursos de acordo com a necessidade do usuário, mostrando-se uma ferramenta para redução de cancelamentos cirúrgicos.


Subject(s)
Humans , Operating Rooms , Appointments and Schedules , Retrospective Studies , Elective Surgical Procedures
3.
Arq. bras. oftalmol ; 81(5): 443-454, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-950482

ABSTRACT

ABSTRACT Nature has always provided an unlimited source of biologically-active compounds. Since the beginning of mankind, humans have sought resources in fauna and flora to treat eye diseases. However, it was only after the Industrial Revolution that extracts of plants and substances of animal origin could be used safely, as has been determined by controlled interventional studies. Two major challenges faced by ocular pharmacology are the following: developing drugs that are able to reduce blindness due to glaucoma; and controlling the pain associated with eye surgery. The search for a drug that effectively lowers intraocular pressure and controls the progression of glaucoma has led to the development of various ocular hypotensive agents, such as physostigmine from the Physostigma venenosum plant. The anesthetic properties of cocaine, extracted from Erythroxylon coca, finally enabled surgical procedures in the eye. Several new natural compounds have been investigated in an attempt to identify substances with the potential to provide additional benefits to eye tissue and vision. Emerging evidence of anti-inflammatory, wound-healing, antimicrobial, antioxidant, antitumor, and antiangiogenic properties attributed to plant extracts and animal tissues has encouraged more investment in research in this area. Despite technological advances in synthesizing drugs, the pharmaceutical industry still seeks new active compounds from natural sources as well as from revisiting already-established naturally derived compounds. Although a large number of naturally-occurring compounds is known, this review article focuses on the bioactive substances with scientifically-proven benefits for ocular tissues.


RESUMO A natureza sempre se forneceu uma fonte inesgotável compostos biologicamente ativos. Desde o início da humanidade, os homens buscaram recursos na fauna e flora para tratar as doenças oculares. Porém, foi somente após a Revolução Industrial que extratos de plantas e substâncias de origem animal puderam ser utilizados com segurança, como foi determinado por estudos controlados de intervenção. Dois grandes desafios enfrentados pela farmacologia foram: desenvolver drogas capazes de reduzir a cegueira pelo glaucoma; e controlar a dor associada à cirurgia ocular. A busca por uma droga que efetivamente reduza a pressão intraocular e controle a progressão do glaucoma levou ao desenvolvimento de diversos hipotensores oculares, como a physostigmine da planta Physostigma venenosum. As propriedades anestésicas da cocaína, extraídas da Erythroxylon coca, finalmente permitiram procedimentos cirúrgicos no olho. Vários novos compostos naturais foram investigados na tentativa de identificar substâncias com potencial para fornecer benefícios adicionais ao tecido ocular e à visão. Evidências emergentes de propriedades anti-inflamatórias, de cicatrização de feridas, antimicrobianas, antioxidantes, antitumorais e antiangiogênicas atribuídas a extratos de plantas e tecidos animais estimularam mais investimentos em pesquisas nessa área. Apesar dos avanços tecnológicos na síntese de drogas, a indústria farmacêutica ainda busca novos princípios ativos a partir de fontes naturais, bem como revisita drogas derivadas já estabelecidas. Embora um grande número de compostos que ocorrem naturalmente seja conhecido, este artigo de revisão concentra-se nas substâncias bioativas com benefícios cientificamente comprovados para os tecidos oculares.


Subject(s)
Humans , Plants, Medicinal/chemistry , Plant Extracts/therapeutic use , Eye Diseases/drug therapy
4.
Rev. bras. oftalmol ; 76(1): 11-16, Jan.-Feb. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-844061

ABSTRACT

RESUMO Objetivo: Avaliar a eficácia de um novo marcador cirúrgico para ajudar na confecção da capsulorrexe anterior analisando o seu dimensionamento e formato, comparando com a capsulorrexe confeccionada manualmente de maneira livre. Métodos: Como experimento, 3 residentes (R3) de Oftalmologia do Hospital Universitário Onofre Lopes (HUOL) e 1 oftalmologista em treinamento, voluntários, realizaram (cada um) 10 capsulorrexes em olhos de porco enucleados. Em 5 olhos foi utilizado o marcador e em outros 5, não. Todos os olhos foram fotografados tendo ao lado uma régua para orientar e calibrar um aplicativo para a avaliação morfométrica do procedimento. O diâmetro alvo foi de 5 mm, cujo perímetro correspondente é 15,7 mm e a área 19,652 mm2. Foram avaliados em cada procedimento: os diâmetros máximo, mínimo e médio, o perímetro, a área e o desvio em relação ao diâmetro e quanto ao aspecto ideal. Resultados: No grupo utilizando o marcador o diâmetro médio foi 5,44mm (±0,89) contra 6,37mm (±0,67) (p=0,001), no grupo no qual não se utilizou o marcador; quanto ao perímetro, 17,52mm (±1,92) no grupo utilizando o marcador contra 20,14mm (±2,09) (p<0,001) sem o marcador e quanto a área, 24,73mm2 (±1,92) com o marcador, contra 32,62mm2 (±6,32) (p<0,001), sem o marcador. Em relação ao aspecto da capsulorrexe 1,26mm (±0,12), contra 1,21mm (±0,7) (p=0,09) e em relação ao desvio de curvatura: 0,87 (±0,05), contra 0,9 (±0,04), (p=0,06) respectivamente. Conclusão: O trabalho mostrou que o marcador avaliado é eficaz para auxiliar a confecção da capsulorrexe conduzindo a resultados melhores que o método a mão livre.


ABSTRACT Purpose: To evaluate the effectiveness of a surgical device that intented to help in the preparation of the anterior capsulorhexis analyzing the design and shape, comparing with capsulorhexis made by free hand. Methods: Three ophthalmology residents(R3) at the HUOL and one surgeon in training, participate in this research as volunteers. Each surgeon perform 5 capsulorhexis in porcine eyes using the device, and five others by free hand as a control. All capsulorhexis were photographed having a ruler as reference to guide and calibrate a computer application for morphometric evaluation (Cambuí Labs, Natal, Brazil). All surgeons aimed to produce a circular continuous capsulorhexis of 5 mm diameter that represents 15,7mm in perimeter and 19,652mm2 in area. Each wet-lab capsulorhexis was evaluated in regard to these criteria: diameter (mean, maximum and minimum), perimeter, area, deviation from the ideal diameter and ideal shape. Results: Compare to control groups, capsulorhexis with the aid of the surgical device showed: 5,44mm ±0,89 vs 6,37mm ±0,67, for capsulorhexis diameter (p=0,001); 17,52mm ±1,92 vs 20,14mm ±2,09 for capsulorhexis perimeter (<0.001); 24,73mm2 ±1,92 vs 32,62mm2 ±6,36 for capsulorhexis area (p<0,001). A tendency for better result with the aid of the surgical device was observed for deviation of an ideal diameter or ideal aspect were appreciated: 0,87mm ±0,05 vs 0,9 ±0,04 for deviation of a curve (p=0,06); 1,26mm ±0,12 vs 1,21mm ±0,7 for the capsulorhexis aspect (p=0,09). Conclusion: Capsulorhexis produced with the aid of the surgical device, significantly improved wet-lab capsulorhexis performance.


Subject(s)
Animals , Capsulorhexis/instrumentation , Capsulorhexis/methods , Lens, Crystalline/surgery , Ophthalmology/education , Swine , Cataract/chemically induced , Equipment Design , Formaldehyde/pharmacology , Lens, Crystalline/drug effects , Methylcellulose/pharmacology , Models, Anatomic
5.
Arq. bras. oftalmol ; 68(2): 167-170, mar.-abr. 2005. tab
Article in English | LILACS | ID: lil-402509

ABSTRACT

OBJETIVO: Determinar a prevalência dos achados oculares das estruturas externas e segmento anterior do olho detectados ao exame biomicroscópico em uma população de estudantes de Natal (RN) - Brasil. MÉTODOS: 1024 escolares do ensino fundamental e médio de escolas públicas e privadas da cidade de Natal foram avaliados de março a junho de 2001 após seleção randomizada prévia. Todos foram submetidos a protocolo de pesquisa pré-estabelecido consistindo em identificação, dados demográficos e exame oftalmológico biomicroscópico com lâmpada de fenda, realizados por oftalmologistas do Hospital Universitário Onofre Lopes. RESULTADOS: As alterações da conjuntiva e das pálpebras foram as mais prevalentes, (10,4% e 6,2% respectivamente). Dentre estas, folículos e papilas conjuntivais representaram os achados mais evidenciados ao exame da conjuntiva (4,2% e 3,0% respectivamente), ao passo que blefarite anterior (3,5%) e meibomite (1,1%) foram as anormalidades mais encontradas nas pálpebras. Ao exame da córnea, íris, cristalino e vítreo anterior, os achados mais freqüentes foram: nubécula (0,5%), restos da membrana pupilar (0,5%), opacidade de cápsula posterior (0,8%) e resquício da artéria hialóide (2,0%). CONCLUSAO: Os achados mais prevalentes acometeram com maior freqüência as estruturas externas do olho (pálpebras e conjuntivas), tendo como seus principais representantes a blefarite anterior e reação folicular da conjuntiva, respectivamente. Já as anormalidades mais evidenciadas na córnea, íris, cristalino e vítreo anterior foram: nubécula, resquício da membrana pupilar, opacidade da cápsula posterior e resquício da artéria hialóide, nesta ordem.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Anterior Eye Segment , Eye Diseases/epidemiology , Brazil/epidemiology , Cross-Sectional Studies , Conjunctiva/ultrastructure , Diagnostic Techniques, Ophthalmological , Conjunctival Diseases/diagnosis , Conjunctival Diseases/epidemiology , Eye Diseases/diagnosis , Prevalence
SELECTION OF CITATIONS
SEARCH DETAIL